A flexible endoscope that fails a leak test, loses angulation or shows a degraded image has to come out of service. The first thing you need is a clear answer about what is wrong and what it will take to fix.

Every repair at RETECH starts with a documented evaluation. You see the findings and a written estimate before any work is done.

Common problems we evaluate

  • Leaks and fluid invasion

    A failed leak test usually points to a damaged bending rubber, a channel perforation or a failed seal. Left alone, fluid can reach the optics and electronics.

  • Angulation and steering

    Reduced tip deflection, free play in the control knobs, or a tip that does not return to neutral, often from stretched or worn angulation wires.

  • Image and light problems

    No image, lines, discoloration or fogging on video scopes, and broken fibers or dim light output.

  • Insertion tube damage

    Kinks, crush marks, bite damage and cuts or peeling in the outer covering.

  • Channel problems

    Blocked or damaged suction and instrument channels, and air/water delivery faults.

  • Distal tip and control body

    Chipped lenses, nozzle damage, cracked housings, sticking buttons and worn valve seats.

Flexible endoscopes are bent, reprocessed and handled many times a day. Most failures build up gradually from that routine handling, which is why a thorough evaluation matters more than a quick fix for the most visible symptom.

What the evaluation covers

  • Leak test
  • Angulation in all four directions
  • Image and light transmission
  • Insertion tube and bending section
  • Suction, air/water and instrument channels
  • Distal tip and lenses
  • Control body, valves and connectors

Before any work begins

You receive a written estimate with the findings and the recommended repair. Nothing is repaired until you approve it. If further damage turns up during the repair, we stop and send a revised estimate for your approval.

What you receive back

  • Your scope, returned with carrier tracking.
  • Documentation of the repair and the final test results.
  • An invoice under the same repair number as the estimate.
  • A private tracking link with status, notes and photos throughout the repair.

Sending a scope

Please request a repair before shipping. We reply with a repair number, the shipping address and packing instructions. Reprocess the scope according to your facility’s procedure before it ships, and never include patient information with the scope or the request.

How it works

  1. 1

    Submit your repair request

    Tell us about the equipment and the problem.

  2. 2

    Send your scope

    We reply with a repair number and shipping instructions.

  3. 3

    Evaluation & written estimate

    We inspect the scope and send findings before any work.

  4. 4

    Repair, testing & return

    Approved work is completed, tested and shipped back.

Have an endoscope that needs attention?

Tell us about the equipment and the problem. We will reply with next steps and shipping instructions.