Gastroscope Repair

Upper GI scopes face their own risks: bite damage to the insertion tube, impacts to the distal tip and lenses, and heavy use of the instrument channel.

We evaluate the scope completely and send you the findings with a written estimate. No work begins without your approval.

Common problems we evaluate

  • Bite damage

    Punctures and compression in the insertion tube, which often lead to leaks.

  • Distal tip and lens damage

    Chipped or scratched lenses, damaged nozzles and cracked tip housings.

  • Leaks

    Failed leak tests from bending rubber damage, channel perforation or tip damage.

  • Angulation

    Reduced deflection, stiffness or a tip that does not return to neutral.

  • Channel wear

    Instrument channel damage from frequent passage of accessories.

Many gastroscope failures start as small damage, such as a single bite mark or a chipped lens edge, that grows with continued use and reprocessing. An evaluation records exactly where things stand before you decide.

What the evaluation covers

  • Leak test
  • Angulation in all four directions
  • Image and light transmission
  • Insertion tube and bending section
  • Suction, air/water and instrument channels
  • Distal tip and lenses
  • Control body, valves and connectors

Before any work begins

You receive a written estimate with the findings and the recommended repair. Nothing is repaired until you approve it. If further damage turns up during the repair, we stop and send a revised estimate for your approval.

What you receive back

  • Your scope, returned with carrier tracking.
  • Documentation of the repair and the final test results.
  • An invoice under the same repair number as the estimate.
  • A private tracking link with status, notes and photos throughout the repair.

Sending a scope

Please request a repair before shipping. We reply with a repair number, the shipping address and packing instructions. Reprocess the scope according to your facility’s procedure before it ships, and never include patient information with the scope or the request.

How it works

  1. 1

    Submit your repair request

    Tell us about the equipment and the problem.

  2. 2

    Send your scope

    We reply with a repair number and shipping instructions.

  3. 3

    Evaluation & written estimate

    We inspect the scope and send findings before any work.

  4. 4

    Repair, testing & return

    Approved work is completed, tested and shipped back.

Have an endoscope that needs attention?

Tell us about the equipment and the problem. We will reply with next steps and shipping instructions.